RDL®

ST-LCR3

Logic Controlled Relay - Dual Alternate Pulse

SKU: ST-LCR3
  • Pulse at the Start of a Logic Signal
  • Pulse at the End of a Logic Signal
  • Relay Contact and Open-Collector Pulse
  • Active High or Active Low Inputs
  • Input Control Voltage From 3.3 to 24 Vdc
  • Control from Switch, Pushbutton, or Logic Circuits
Recommended Power Supply ( Not Included )
PS-24AS (USA)PS-24AX (International)
Category:

Description

The ST-LCR3 is ideally suited to applications where momentary pulses are needed from a single control signal. The module provides a momentary pulse when a logic signal at its input first becomes active. A separate momentary pulse is provided when the logic signal at the module input becomes inactive.

Two logic inputs are available on the ST-LCR3. Either of these inputs may be used. Terminal 1 is internally pulled high to +5 Vdc. This input becomes active when an external closure or open-collector pulls the terminal to ground. The external switching device does not need to pull the terminal high, however the terminal may be pulled high with any voltage from +3.3 Vdc to +24 Vdc without any risk of damage to the ST-LCR3 input. Terminal 3 is internally pulled to ground. This input becomes active when an external closure or logic device applies a positive voltage from +3.3 Vdc to + 24 Vdc.

When the input being used first becomes active the START PULSE output from the module is triggered. When the input first becomes inactive (after first being active) the END PULSE output from the module is triggered. Both the start and end pulses have a nominal duration of 250 ms.

Each pulse output provides both an open-collector SLAVE terminal and relay contacts. The SLAVE terminal may be used to control other RDL modules and a variety of other equipment. The relay contacts may be used to control modules or equipment that do not operate from open-collector control.

Specifications

Inputs (2):Logic High or Logic Low (Low = ground, High = 3.3 Vdc to 24 Vdc)
Outputs (2):Open collector @ 25 mA suitable to drive indicators or slave LCRs.
Switching Contacts:Single Pole Relay Contacts (2)
Maximum Switching Power:60 W (220 Vdc, 125 Vac, 2 A)
Ambient Operating Environment0° C to 55° C
Power Requirement:GROUND-REFERENCED, 24 Vdc @ 100 mA (assuming 20 mA max load at SLAVE output)
Package Type:Cardboard Box
WEEE weight:0.145 lbs.
Shipping Weight:0.2 lbs.
Tariff code:8543.70.9860
Package Dimensions:2 x 2 x 4 in.

Related Products

Switching
  • ST-LCR1

    Logic Controlled Relay - Momentary

  • ST-LCR1H

    High Power Logic Controlled Relay - 8 A

  • ST-LCR2

    Logic Controlled Relay - Latching

EMC
  • STS-RF1

    Shielded Chassis for STICK-ON module

Related Products

General Wiring Accessories
  • DTB

    STICK-ON® Series Detachable Terminal Block

General Mounting Accessories
  • DMK-5

    Detachable Mounting Kit for RDL Modules

  • MB-1

    Mounting Kit - RU, ST and TX Series

  • SR-4

    STICK-ON Series Mounting Rack - 7 modules

DIN Rail Mounting Accessories
  • DRA-35S

    STICK-ON DIN Rail Adapter - 1 module

  • DRA-35S6

    STICK-ON DIN Rail Adapter - 6 modules

STICK-ON® Mounting Accessories
  • SMK-12

    STICK-ON Mounting Plate

  • SR-10

    STICK-ON Series 19" Mounting Rack - 10 modules

  • SR-12A

    STICK-ON Series 19" Mounting Rack - 12 modules

  • ST-PBR4

    STICK-ON Mounting Bracket

  • ST-RRB1

    Rear rack rail mounting kit for any STICK-ON module

  • STR-19A

    STICK-ON Series 19" Racking System - 12 modules

  • STR-19B

    STICK-ON Series 19" Racking System - 10 modules

  • STR-H6A

    10.4" Rack Mount for 6 STICK-ON Series Products

Dimensions

ST-LCR3

Downloads

DocumentsFormat
Datasheet PDF
CAD FilesUnitsFormat
Engineering Functional Block American DXF
Panel Diagram - End American DXF
Panel Diagram - Front American DXF
Panel Diagram - End Metric DXF
Panel Diagram - Front Metric DXF
High Res ImagesFormat
st-lcr3.zip TIF
Declaration of Conformity
Download

Diagrams

Related Products

  • AMS-PB1

    Momentary SPDT Pushbutton - fits all AMS mounts

  • AMS-SW2

    Rocker Switch DPDT - fits all AMS mounts

Where To Buy

Direct Dealer Program

Becoming an RDL direct dealer is quick and easy. To become a direct dealer, your company must meet the following requirements:

  • Must be an A/V contractor, sound contractor or system integrator
  • Must possess a current resale certificate for your state
Click here to submit a new direct dealer account inquiry

Where To Buy

Company Address Phone Link
Authorized Distributor Link
State name View
You're viewing: ST-LCR3
Add to cart
Shopping cart close