RDL®

FP-NML2

Network to Mic/Line Interface

SKU: FP-NML2
  • Adapts Standard Audio Amplifiers to a Dante Network
  • Converts Two Dante Network Audio Signals to Professional Line Level
  • Each Output is Switch-Selectable for Mic or Line Level
  • Line-Level Outputs Provide +4 dBu with > 18 dB Headroom
  • Exceptional Low-Noise and Low-Distortion Performance
  • Crosstalk is Below the Noise Floor
  • 24 Vdc Pass-Through Jack for Power Supply Sharing with RDL Amplifiers (FP-NML2)
  • High Resolution 24 Bit Digital to Analog Conversion
  • Legendary RDL Analog Filtering Enhances Superb Audio Performance
  • Outputs Mute when Digital Audio Inputs are Inactive
  • Normal or Hot-Standby Operation from PoE (Model FP-NML2P)
  • Equipped for Rack Mounting or Surface Mounting
Recommended Power Supply
PS-24AS (USA)PS-24AX (International)
TAA Compliant
Category:

Description

The FP-NML2 modules are Dante audio network interface products compatible with mic-level or line-level audio equipment inputs. These modules are designed to be mounted in equipment racks, closets, conference tables and on shelves or backboards in commercial/industrial installations.

APPLICATION: The FP-NML2 is a high quality converter that provides professional line-level outputs from two Dante network audio channels. Each line output provides +4 dBu balanced for a network digital audio level of -18 dBFS. The professional output directly interfaces with other professional and commercial equipment without the need for additional gain. Crosstalk is below the noise floor between all outputs across the entire audio spectrum. The noise floor is better than 80 dB below operating level with greater than 18 dB of headroom. Each output is equipped with a recessed mic/line switch that provides 50 dB of attenuation to feed the microphone input of a mixer-amplifier or other equipment with mic inputs.

The FP-NML2 is powered from an external 24 Vdc power supply, available separately. The FP-NML2P is equipped to operate from a PoE enabled network switch. The FP-NML2P will reserve power from the switch even while being powered from an external 24 Vdc supply. If PoE power and an external 24 Vdc supply are both feeding an FP-NML2P, the unit will run from the external supply and will seamlessly switch over to PoE power upon loss of the external supply.

The FP-NML2 includes a dc output jack and extension cable that allows it to be operated from a common power supply with RDL FLAT-PAK amplifiers. One audio output connects to the FLAT-PAK amplifier input, and the second output may be connected to an additional amplifier.

The FP-NML2’s superior performance specifications make it ideally suited to the most demanding installations, and an exceptional value in commercial networked audio systems.

The FP-NML2 is constructed in a durable, professional all-metal enclosure suitable for free-standing, surface-mounted or rack-mounted operation. This full-featured product is engineered and manufactured in the U.S.A for continuous duty in demanding installations. Built to last. Built to outperform.

Specifications

Network Connector:RJ45 with Link and Speed indicators
Digital Audio Ethernet Protocol:Dante
Transmission Rate:100 Mbps
Sample Rates Supported:44.1 kHz, 48 kHz (default)
Bit Depth Supported:24 bits
Audio Operating Levels:-18 dBFS = +4 dBu
Outputs (2):Balanced, detachable terminal block
Output Level:+4 dBu (nominal)
Output Impedance:150 Ω balanced; 75 Ω unbalanced
Frequency Response:20 Hz to 20 kHz (± 0.5 dB)
THD+N:< 0.1%
Noise below +4 dBu:< -80 dB (output active); < -95 dB (outputs muted)
Crosstalk:< 90 dB (1 kHz); < 80 dB (20 Hz to 20 kHz)
Headroom above +4 dBu:> 18 dB
Indicators (3):Ethernet Link and Speed, SYNC
Power Connections (2):Power Jack; 24 Vdc Pass-Through
Ambient Operating Environment:0° C to 40° C
Power Requirement:24 Vdc @ 100 mA, or PoE (FP-NML2P)
PoE (FP-NML2P):Class 0, IEEE 802.3af
Dimensions:4.85" (12.3 cm) W; 1.75" (4.45 cm) H; 3.25" (8.26 cm) D
Package Type:Cardboard Box
Package Dimensions:4.375 x 4.8 x 2.25 in.
Shipping Weight:0.791 lbs. (FP-NML2); 0.816 lbs. (FP-NML2P)
WEEE weight:0.645 lbs. (FP-NML2); 0.67 lbs. (FP-NML2P)
Tariff code:8543.70.9100

Related Products

Dante®
  • FP-NML2P

    FP-NML2P

    Network to Mic/Line Interface

  • FP-NML2V

    FP-NML2V

    Network to Mic/Line Interface with VCA

  • FP-NML2VP

    FP-NML2VP

    Network to Mic/Line Interface with VCA

  • RU-BNF

    RU-BNF

    Format-A Bi-Directional Network Interface

  • RU-BNFP

    RU-BNFP

    Format-A Bi-Directional Network Interface

  • RU-FN

    RU-FN

    Format-A to Network Interface

  • RU-FNP

    RU-FNP

    Format-A to Network Interface

  • RU-LB2

    RU-LB2

    Line-Level Bi-Directional Network Interface

  • Line-Level Bi-Directional Dante Interface

    RU-LB2P

    Line-Level Bi-Directional Dante Interface

  • RU-LB4

    RU-LB4

    Line-Level Bi-Directional Network Interface

  • Line-Level Bi-Directional Network Interface

    RU-LB4P

    Line-Level Bi-Directional Network Interface

  • RU-MLB2

    RU-MLB2

    Mic/Line Bi-Directional Network Interface

  • Mic/Line Bi-Directional Network Interface

    RU-MLB2P

    Mic/Line Bi-Directional Network Interface

  • Dante 4x4 Audio Interface

    RU-MLB4

    Mic/Line Bi-Directional Network Interface

  • Mic/Line Bi-Directional Dante Interface

    RU-MLB4P

    Mic/Line Bi-Directional Network Interface

  • RU-NFD

    RU-NFD

    Network to Format-A Interface/Distributor

  • RU-NFDP

    RU-NFDP

    Network to Format-A Interface/Distributor

  • RU-NL2

    RU-NL2

    Network to Line Level Interface

  • RU-NL2P

    RU-NL2P

    Network to Line Level Interface

  • RU-NL4

    RU-NL4

    Network to Line Level Interface

  • RU-NL4P

    RU-NL4P

    Network to Line Level Interface

Power Amplifiers
  • FP-PA18

    FP-PA18

    18 W Mono Audio Amplifier - 8 Ω, with Power Supply

  • FP-PA18H

    FP-PA18H

    18 W Mono Hi-Temp Audio Amplifier - 8 Ω, with Power Supply

  • HD-MA35A

    HD-MA35A

    35 Watt Mixer Amplifier with Power Supply - Constant Voltage Output 25 V, 70 V or 100 V

  • HD-MA35U

    HD-MA35U

    35 Watt Mixer Amplifier - 4 Ohm / 8 Ohm, with Power Supply

  • HD-MA35UA

    HD-MA35UA

    35 Watt Mixer Amplifier - 25, 70, 100 V, with Power Supply

  • HD-PA35

    HD-PA35

    35 Watt Power Amplifier with Power Supply - Low Impedance Output 4 Ohm or 8 Ohm

  • HD-PA35A

    HD-PA35A

    35 Watt Power Amplifier with Power Supply - Constant Voltage Output 25 V, 70 V or 100 V

  • HD-RA35U

    HD-RA35U

    35 Watt Remote Mixer Amplifier - 4 Ohm / 8 Ohm, with Power Supply

  • RU-PA40D

    RU-PA40D

    40 W Stereo Audio Amplifier with VCA - 8 Ω, with Power Supply

  • RU-PA518

    RU-PA518

    10 W Stereo / 18 W Mono Audio Amplifier - 8 Ω

  • Mono 18W Amplifier

    ST-PA18

    18 W Mono Audio Amplifier - 8 Ω

  • ST-PA2

    ST-PA2

    2 W Mono Audio Amplifier - 8 Ω

  • Compact Audio Amplifier

    ST-PA6

    6 W Mono Audio Amplifier - 8 Ω

  • TX-PA40D

    TX-PA40D

    40 W Stereo Audio Amplifier - 8 Ω, with Power Supply

Audio
  • FP-PA20

    FP-PA20

    20 W Mono Audio Amplifier - 8 Ω

  • FP-PA20A

    FP-PA20A

    20 W Mono Audio Amplifier - 70 V or 100 V

  • FP-PA20B

    FP-PA20B

    20 W Mono Audio Amplifier - 25 V

  • Constant voltage amplifier

    FP-PA35A

    35 W Mono Audio Amplifier - 25 V, 70 V or 100 V, with Power Supply

Headphone Amplifiers
  • RU-SH1

    RU-SH1

    Stereo Headphone Amplifier - RACK-UP Series

Related Products

Flat-Pak™ Mounting Accessories
  • FP-HRA

    FP-HRA

    10.4" Rack Mount for FLAT-PAK Series Products

  • FP-RRA

    FP-RRA

    Rack Adapter FLAT-PAK Series - 19" Fixed

  • FP-RRAH

    FP-RRAH

    Rack Adapter FLAT-PAK Series - 19" Hinged

  • FP-RRB1

    FP-RRB1

    Rear rack rail mounting kit for any FLAT-PAK module

DIN Rail Mounting Accessories

Dimensions

FP-NML2

Downloads

DocumentsFormat
Datasheet PDF
CAD FilesUnitsFormat
Engineering Functional Block American DXF
Panel Diagram - Front American DXF
Panel Diagram - Rear American DXF
Panel Diagram - Front Metric DXF
Panel Diagram - Rear Metric DXF
High Res ImagesFormat
fp-nml2.zip TIF
Declaration of Conformity
Download

Diagrams

Where To Buy

Direct Dealer Program

Becoming an RDL direct dealer is quick and easy. To become a direct dealer, your company must meet the following requirements:

  • Must be an A/V contractor, sound contractor or system integrator
  • Must possess a current resale certificate for your state
Click here to submit a new direct dealer account inquiry

Where To Buy

Company Address Phone Link
Authorized Distributor Link
State name View
FP-NML2
You're viewing: FP-NML2
Add to cart
Shopping cart close